RO Membrane Systems
BWRO | BRACKISH WATER RO SYSTEMS
Commercial
Daily Capacity Range:
600 to 32,000 GPD
(2 to 121 M³/day)
INDUSTRIAL
Daily Capacity Range:
28,800 to 2M GPD
(109 to 7,570 M³/day)
SWRO | SEAWATER RO SYSTEMS
Commercial
Daily Capacity Range:
380 to 10,000 GPD
(1.4 to 38 M³/day)
INDUSTRIAL
Daily Capacity Range:
8,000 to 660,000 GPD
(30 to 2,500 M³/day)
NF | NANOFILTRATION SYSTEMS
Commercial
Daily Capacity Range:
13,000 to 32,000 GPD
(50 to 121 M³/day)
INDUSTRIAL
Daily Capacity Range:
190,000 to 855,000 GPD
(719 to 3,236 M³/day)
UF | ULTRAFILTRATION SYSTEMS
SOLAR POWERED UF
OFF-GRID UF Systems
Flow Rate Varies
INDUSTRIAL
Daily Capacity Range:
10,000 to 1,037,000 GPD
(38 to 3,928 M³/day)
CIP | MEMBRANE CLEANING SYSTEMS
FOR 4" MEMBRANES
Up to 3 Pressure Vessels
Flowrates: 8 to 30 GPM
(1.8 to 6.8 M³/hr)
FOR 8" MEMBRANES
Up to 6 Pressure Vessels
Flowrates: 40 to 210 GPM
(9 to 48 M³/hr)
Water wave technologies have over 5 years of experience all over Pakistan. The best supplier of water treatment with a wide range of applications, from reverse osmosis systems to nanofiltration, ultrafiltration, and membrane cleaning systems. The units were outlined to remove different impurities and produce ultra-clean and hygienic water
Water wave technologies manufacture designs and give the most advanced reverse osmosis solution and membrane systems in industries. We are proud of ourselves for our reverse osmosis/water treatment systems. It is that kind of system, which gives us the reputation for quality and efficiency above all others water membrane industries. Reverse Osmosis (RO) technology, is also called hyperfiltration. It is used in our municipal, commercial, and industrial water treatment systems to purify water by removing salts, contaminants, heavy metals, and other impurities
We have different pre-engineered models, as well as custom treatment systems from less containerized systems to full water treatment plants with specific purification of water according to your needs.
Reverse osmosis systems work by applying a high-pressure pump to a concentrated solution of unfiltered water. It could be in the form of seawater, brackish, or tap water. The process of water forces the water through a semipermeable membrane, leaving virtually dissolved the salts and other
Substances in its chamber. It is the kind of water you were looking to purify using reverse osmosis systems. Which determine the pump will be needed to use to see the better and more efficient results. The Seawater requires bigger and higher pressure pumps compared to tap water or brackish water as long as it contains a higher content of total dissolved solids (TDS). Reverse osmosis systems are necessary to protect the membranes working applies pretreatment from fouling and failing prematurely. The degradation of the reverse osmosis membrane occurs due to the increase of foulants such as calcium carbonate, magnesium carbonate, iron, manganese, iron, manganese, etc.
Reverse osmosis systems definitely remove fluoride because, it is extremely effective at removing most impurities in water, and fluoride is one of the parts from it. Still, the efficiency at which the process filters fluoride from water trust on its capacity to block fluoride molecules to flow. Eventually, the size of the openings within the reverse osmosis membrane will be a decisive factor in that, what passes through it. In general, the size of fluoride molecules is huge and enormous to course through even in the smallest openings of reverse osmosis systems.
RO systems have the ability to remove up to 99% of the lead and other material like metals in water, which is passed through its membranes. Reverse osmosis systems are particularly the most preferred and favorable water filtration systems when it comes to lead removal. It is the beneficial rate that allows for consumable hygienic water for humans, animals, and plants.
Reverse osmosis membranes can be considered as the main core program of reverse osmosis systems. All the elements are responsible for the actual filtration process within these systems. So we must ensure to be of the highest quality the process. Several RO handlers decide to choose the lower quality membranes for the purposes of saving operational costs. The stark is the major difference in performance among high quality and low quality in reverse osmosis membranes by the former producing more effective filtration results in the process.
The three primary benefits and advancement of RO operations are energy-saving, fouling resistance, and Greater rejection percentage, which requires a superior membrane element.
Quality reverse osmosis membranes can be achieved from major brands such as Dow Filmtec, Hydranautics, and Toray.
If you have any water treatment needs, please give us an Email: info@waterwavetech.com and we will be happy to provide you with a quote or any information you may need.
NEXT STEP TO CRISP, WATER
SOLUTION & MORE
Contact Your Water Wave Tech expert to Learn more, Schedule Your Free Queries and Consultation, or Request Pricing.